An error occurred while making the requested connection when Launching
Applications from a Legacy Citrix Farm through Web Interface 5.x
When
administrators try to integrate legacy Citrix farm with XenApp6 or 6.5 farm in
the same web interface and launch application they will get the below attached
error.
Cause: Web
Interface 5.x (5.2, 5.3, 5.4) by default, are not compatible with Citrix
metaframe xp, Presentation server 3.0 & 4.0 Server for Windows or UNIX. An
additional manual site configuration step is required.
Resolution:
·
On the Web Interface 5.x server, locate the WebInterface.conf
file (\Inetpub\wwwroot\Citrix\XenApp\Conf) and open it with a text editor.
·
Locate the following entry around “RequireLaunchReference=On”
·
Replace it with the following entry: “RequireLaunchReference=Off”
·
Save the WebInterface.conf file and test.
·
Users should be able to launch applications
from the Legacy Citrix farm successfully.
0 comments: